(:title APM.PRED_TIME - APMonitor Option:) (:keywords APM.PRED_TIME, Optimization, Estimation, Option, Configure, Default, Description:) (:description Time for each step in the horizon:)

 Type: Floating Point, Input or Output (with CSV read)
 Default Value: 60.0
 Description: Time for each step in the horizon

PRED_TIME is the prediction time of a controller beyond the control horizon. PRED_TIME is typically set to a larger value than CTRL_TIME to reach steady state conditions but also have fine resolution for near term movement of MVs. When CSV_READ is on and the horizon time points are specified from the data file, the CTRL_TIME and PRED_TIME are set equal to the time increment of the first time step.